Basic Wire & Cable Co. - Part # 11-1524, Type SOOW Flexible Cords
Call Us Today: (800) 227-4292 | E-mail: basicwire@basicwire.com
Control, Tray, Power Cables - 600V-2000V Instrumentation, Electronic, Signal Cables Armored, Control, Power Cables, Teck Type Flexible Portable Cords Flexing Portable Mining Cables Power MV-105 Lighting Cables Bare Copper Wires Building Wires Switchboard Wires
 Search Catalog
      GO   
 All Categories    Type SOOW Flexible Cords
All Categories > Armored Control Power Cables > TECK-90 Type Interlocked Armor Power Cables > Type SOOW Flexible Cords > Part # 11-1524  
Request Information

Part # 11-1524 Type SOOW Flexible Cords




    Print Printable Page  
    Email Email This Page  
    Save To Favorites Save To Favorites
  

Type Soow Flexible Cord

larger image
Type SOOW Flexible Cords
  • Flexible stranded copper
  • EPR Insulation
  • CPE Jacket
  • 600 Volts, 90 Deg. C.




Specifications · Applications · Construction · Standards

Specifications

Conductor Size

16 AWG

No. of Conductors

3

Strand

26/30

O. D. (in)

0.39

Conductors Insulation (mils)

30

Jacket Insulation (mils)

60

Weight (lbs/m)

95

AMPS1

10

Insulation

Ethylene Propylene Rubber (EPR)

Jacket

Chlorinated Polyethylene (CPE)

Rated Circuit Voltage

600 V

Recommended Operating Temperature

90 ºC

Conductor Material

Stranded Copper

Note

Information on this sheet subject to change without notice.

Shipping Tolerance

± 10%
1 Ampacity values based on NEC Table 400-5(A).
Color-code sequence is white, black, green, red.


Applications
Type Soow flexible cords are permitted for use per Article 400 of the NEC in wiring for industrial machinery, motors and associated equipment, portable tools and equipment, and temporary electrical power and lighting installations for construction sites. Also suitable for indoor and outdoor use, for use in dry locations not to exceed min. -40 deg. C. or max. 90 deg. C., wet locations and other applicable locations; or when exposed to oil or coolant at temperatures not to exceed 60 deg. C. Ideal for flex applications in harsh environments where the highest degree of oil resistance and extended service life are essential.



Construction
Flexible stranded copper conductors, heat, moisture and oil resistant EPR (Ethylene-Propylene-Rubber) insulated, color-coded (Color-code sequence is white, black, green, red.) conductors cabled with fillers and a separator wrapped around the assembly to promote easier jacket removal, heat, moisture and oil resistant flexible CPE (Chlorinated Polyethylene) jacket overall, surface printed.



Standards
  1. Copper conductors per ASTM B-3 & B-174.
  2. Cables conform to UL-62, Flexible Cord and Fixture Wire.
  3. Cables conform to requirements of Federal and Military Specification JC-580B.




 DOWNLOADS 

 width= Conductor Color Coding Methods
(PDF, 267KB)


Request Information
Site created by ThomasNet Web Solutions